{"id":2680,"date":"2026-01-23T10:45:34","date_gmt":"2026-01-23T09:45:34","guid":{"rendered":"https:\/\/wesselweb.headandcode.dev\/oil-temperature-controller\/"},"modified":"2026-07-09T23:05:22","modified_gmt":"2026-07-09T21:05:22","slug":"oil-temperature-controller","status":"publish","type":"page","link":"https:\/\/wessel-hydraulik.de\/en\/oil-temperature-controller\/","title":{"rendered":"Oil Temperature Controller"},"content":{"rendered":"\n<div class=\"gb-element-b3337877 wh-hero wh-hero--image\">\n<div class=\"gb-element-b07c2792 wh-hero__content \">\n<h1 class=\"gb-text wh-hero__title\"><strong>Oil Temperature Controller<\/strong><\/h1>\n\n\n\n<p class=\"gb-text gb-text-745317cd wh-hero__subtitle\">Application description<\/p>\n<\/div>\n<\/div>\n\n<div class=\"wh-tiles\">\n<div class=\"gb-element-c49075ab\">\n<h2 class=\"gb-text gb-text-1969cbe8\">Oil Temperature Controller OTC-A1<\/h2>\n\n\n\n<p class=\"gb-text gb-text-f167af0c\">The valve is used in the cooler circuit of hydraulically operated machines. In the bypass to the oil cooler, it controls the amount that flows to the tank or through the cooler. The oil temperature controller enables temperature-dependent control of the oil flow. Using a thermocouple, a valve spool is continuously switched from its open position to a closed position.    <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This causes a pressure increase in the cooling pump circuit, which leads to an increase in the flow rate through the cooler. The valve is open at an oil temperature below 40\u00b0C, so that the oil flow returns to the tank uncooled. Above 55\u00b0C, the entire oil flow passes through the oil cooler.  <\/p>\n<\/div>\n<\/div>\n\n<div class=\"gb-element-a8f64ca5\">\n<div class=\"gb-element-5473df5a\">\n<div class=\"gb-element-79ea1676\">\n<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"180\" class=\"gb-media-fb976e24\" alt=\"OTC-A1_137.902.\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/OTC-A1_137.902.101.9-138.902.101.9_20x12-300x180.jpg\" title=\"OTC-A1_137.902.101.9-138.902.101.9_20x12\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/OTC-A1_137.902.101.9-138.902.101.9_20x12-300x180.jpg 300w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/OTC-A1_137.902.101.9-138.902.101.9_20x12-1024x615.jpg 1024w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/OTC-A1_137.902.101.9-138.902.101.9_20x12-768x461.jpg 768w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/OTC-A1_137.902.101.9-138.902.101.9_20x12.jpg 1181w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\n<\/div>\n\n\n\n<div>\n<h2 class=\"gb-text gb-text-172030b3\"><strong>Features<\/strong><\/h2>\n\n\n\n<p class=\"gb-text\">&#8211; Connection M33x2, ISO 9974-1<br\/>&#8211; Inlet flow rate: 250 l\/min &#038; 400 l\/min<br\/>&#8211; Temperature-dependent flow restriction<br\/>&#8211; Robust function due to high switching forces<br\/>&#8211; Easy installation<br\/>&#8211; Continuous adjustment of the flow cross-section<br\/>&#8211; Valve switches thermally with a time delay<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-494cffc3\">\n<h2 class=\"gb-text gb-text-25db1b89\"><strong>Schematic<\/strong><\/h2>\n\n\n\n<img loading=\"lazy\" decoding=\"async\" width=\"327\" height=\"215\" class=\"gb-media-37a7a29f\" alt=\"oil_temp\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/oil_temp.jpg\" title=\"oil_temp\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/oil_temp.jpg 327w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/oil_temp-300x197.jpg 300w\" sizes=\"auto, (max-width: 327px) 100vw, 327px\" \/>\n<\/div>\n\n\n\n<div class=\"gb-element-a627f053\">\n<h2 class=\"gb-text gb-text-1c1940b5\"><strong>Applications<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Excavator<\/li>\n\n\n\n<li>Cranes<\/li>\n\n\n\n<li>Telehandler<\/li>\n\n\n\n<li>Chipper<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"gb-element-f08ded42\">\n<section class=\"wh-doc\" style=\"--wh-doc-bg: #0169AE\">\n  <div class=\"wh-doc__inner\">\n    <div class=\"wh-doc__preview\">\n              <img decoding=\"async\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Cover_OTC_A1.jpg\" alt=\"OTC-A1_D-1-1.pdf\" loading=\"lazy\">\n          <\/div>\n\n    <div class=\"wh-doc__content\">\n              <h3 class=\"wh-doc__title\">OTC-A1 data sheet<\/h3>\n      \n              <div class=\"wh-doc__meta\">442.10 KB<\/div>\n      \n      <a class=\"wh-doc__btn\" href=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/OTC-A1_D-1-1.pdf\" download>\n        <span class=\"wh-doc__btnIcon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"17\" height=\"17\" viewBox=\"0 0 17 17\" fill=\"none\">\n<path d=\"M1.5 14.8333L14.8333 1.5M14.8333 1.5H1.5M14.8333 1.5V14.8333\" stroke=\"#0F2D65\" stroke-width=\"3\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/>\n<\/svg><\/span>\n        Download OTC-A1 data sheet      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div>\n<\/div>\n\n<div>\n<div class=\"gb-element-64bdb44f\">\n<section class=\"wh-contact\">\n  <div class=\"wh-contact__left\">\n    <h2>HOW CAN WE HELP YOU?<\/h2>\n  <\/div>\n\n  <div class=\"wh-contact__right\">\n    <div class=\"wh-contact__info\">\n              <div class=\"wh-contact__label\">Head of Sales &#8211; Field Sales &amp; Development<\/div>\n      \n      \n      <div class=\"wh-contact__name\">Dr.-Ing. Gerald Fees<\/div>\n\n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-telephone-fill\" viewBox=\"0 0 16 16\"> <path fill-rule=\"evenodd\" d=\"M1.885.511a1.745 1.745 0 0 1 2.61.163L6.29 2.98c.329.423.445.974.315 1.494l-.547 2.19a.68.68 0 0 0 .178.643l2.457 2.457a.68.68 0 0 0 .644.178l2.189-.547a1.75 1.75 0 0 1 1.494.315l2.306 1.794c.829.645.905 1.87.163 2.611l-1.034 1.034c-.74.74-1.846 1.065-2.877.702a18.6 18.6 0 0 1-7.01-4.42 18.6 18.6 0 0 1-4.42-7.009c-.362-1.03-.037-2.137.703-2.877z\"><\/path><\/svg><\/span>\n          <a href=\"tel:044219911-54\">\n            04421 9911-54          <\/a>\n        <\/div>\n      \n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-envelope-fill\" viewBox=\"0 0 16 16\"> <path d=\"M.05 3.555A2 2 0 0 1 2 2h12a2 2 0 0 1 1.95 1.555L8 8.414zM0 4.697v7.104l5.803-3.558zM6.761 8.83l-6.57 4.027A2 2 0 0 0 2 14h12a2 2 0 0 0 1.808-1.144l-6.57-4.027L8 9.586zm3.436-.586L16 11.801V4.697z\"><\/path><\/svg><\/span>\n          <a href=\"mailto:info@wessel-hydraulik.de\">\n            info@wessel-hydraulik.de          <\/a>\n        <\/div>\n      \n          <\/div>\n\n          <div class=\"wh-contact__img\">\n        <img decoding=\"async\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2025\/12\/Gerrald-Fees.jpg\" alt=\"Dr.-Ing. Gerald Fees\" loading=\"lazy\">\n      <\/div>\n      <\/div>\n<\/section>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Oil Temperature Controller Application description Oil Temperature Controller OTC-A1 The valve is used in the cooler circuit of hydraulically operated machines. In the bypass to the oil cooler, it controls the amount that flows to the tank or through the cooler. The oil temperature controller enables temperature-dependent control of the oil flow. Using a thermocouple, &#8230; <a title=\"Oil Temperature Controller\" class=\"read-more\" href=\"https:\/\/wessel-hydraulik.de\/en\/oil-temperature-controller\/\" aria-label=\"Read more about Oil Temperature Controller\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":70,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2680","page","type-page","status-publish"],"acf":[],"_links":{"self":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2680","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/comments?post=2680"}],"version-history":[{"count":2,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2680\/revisions"}],"predecessor-version":[{"id":2684,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2680\/revisions\/2684"}],"wp:attachment":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/media?parent=2680"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}