{"id":2687,"date":"2026-01-23T10:14:01","date_gmt":"2026-01-23T09:14:01","guid":{"rendered":"https:\/\/wesselweb.headandcode.dev\/6-2-directional-control-valve-d62-2x\/"},"modified":"2026-07-09T23:06:14","modified_gmt":"2026-07-09T21:06:14","slug":"6-2-directional-control-valve-d62-2x","status":"publish","type":"page","link":"https:\/\/wessel-hydraulik.de\/en\/6-2-directional-control-valve-d62-2x\/","title":{"rendered":"6\/2 Directional Control Valve D62-2X"},"content":{"rendered":"\n<div class=\"gb-element-b3337877 wh-hero wh-hero--image\">\n<div class=\"gb-element-b07c2792 wh-hero__content \">\n<h1 class=\"gb-text wh-hero__title\"><strong>6\/2-way directional valve<\/strong><\/h1>\n\n\n\n<p class=\"gb-text gb-text-745317cd wh-hero__subtitle\">Application description<\/p>\n<\/div>\n<\/div>\n\n<div class=\"wh-tiles\">\n<div class=\"gb-element-c49075ab\">\n<h2 class=\"gb-text gb-text-1969cbe8\">6\/2-way directional valve D62-2X 150, 250, 400 l\/min&nbsp;&nbsp;<\/h2>\n\n\n\n<p class=\"gb-text gb-text-f167af0c\">A 6\/2-way directional valve allows the volume flow downstream of a main section to be distributed to a choice of 2 consumers.<br\/>The directional valves are available in two versions: 6-3 directional valve with a middle position, 6-2 directional valve without a middle position.<br><br>Without a middle position, the main consumer is activated when the directional valve is in the unswitched state. In the switched state, the new additional consumer is operated. Switching is performed hydraulically or electrically. In the electrical version, the control pressure required for the switching process is taken from the high-pressure supply line, so that no additional pilot pressure needs to be provided.<br\/>The valves are not leak-free. Pressure protection for the additional consumer must be installed externally.    <br><br>In the 6\/3 version, the middle position is assumed when both input lines are depressurized. In this position, all inputs and outputs are blocked against each other. <\/p>\n<\/div>\n<\/div>\n\n<div class=\"gb-element-a8f64ca5\">\n<div class=\"gb-element-5473df5a\">\n<div class=\"gb-element-79ea1676\">\n<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"180\" class=\"gb-media-fb976e24\" alt=\"\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/Wegeventile-S62_D62-2X_20x23_150dpi_1181x709-300x180.jpg\" title=\"Directional valves S62_D62-2X_20x23_150dpi_1181x709\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/Wegeventile-S62_D62-2X_20x23_150dpi_1181x709-300x180.jpg 300w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/Wegeventile-S62_D62-2X_20x23_150dpi_1181x709-1024x614.jpg 1024w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/Wegeventile-S62_D62-2X_20x23_150dpi_1181x709-768x461.jpg 768w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/Wegeventile-S62_D62-2X_20x23_150dpi_1181x709.jpg 1182w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\n<\/div>\n\n\n\n<div>\n<h2 class=\"gb-text gb-text-172030b3\"><strong>Features<\/strong><\/h2>\n\n\n\n<p class=\"gb-text\">&#8211; direct and pilot operated<br\/>&#8211; maximum operating pressure of 420 bar<br><br><br><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-494cffc3\">\n<h2 class=\"gb-text gb-text-25db1b89\"><strong>Circuit Diagram<\/strong><\/h2>\n\n\n\n<img loading=\"lazy\" decoding=\"async\" width=\"795\" height=\"716\" class=\"gb-media-37a7a29f\" alt=\"Circuit_diagrams_new\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu.jpg\" title=\"Circuit_diagrams_new\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu.jpg 795w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu-300x270.jpg 300w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu-768x692.jpg 768w\" sizes=\"auto, (max-width: 795px) 100vw, 795px\" \/>\n<\/div>\n\n\n\n<div class=\"gb-element-a627f053\">\n<h2 class=\"gb-text gb-text-1c1940b5\"><strong>Applications<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Excavator<\/li>\n\n\n\n<li>Wheel loader<\/li>\n\n\n\n<li>Material handling machines<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"gb-element-f08ded42\">\n<section class=\"wh-doc\" style=\"--wh-doc-bg: #0169AE\">\n  <div class=\"wh-doc__inner\">\n    <div class=\"wh-doc__preview\">\n              <img decoding=\"async\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/cover_D62.jpg\" alt=\"D62_D-4.pdf\" loading=\"lazy\">\n          <\/div>\n\n    <div class=\"wh-doc__content\">\n              <h3 class=\"wh-doc__title\">Data sheet D62 D-4<\/h3>\n      \n              <div class=\"wh-doc__meta\">704.66 KB<\/div>\n      \n      <a class=\"wh-doc__btn\" href=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/D62_D-4.pdf\" download>\n        <span class=\"wh-doc__btnIcon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"17\" height=\"17\" viewBox=\"0 0 17 17\" fill=\"none\">\n<path d=\"M1.5 14.8333L14.8333 1.5M14.8333 1.5H1.5M14.8333 1.5V14.8333\" stroke=\"#0F2D65\" stroke-width=\"3\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\/>\n<\/svg><\/span>\n        Download data sheet D62 D-4      <\/a>\n    <\/div>\n  <\/div>\n<\/section>\n<\/div>\n<\/div>\n\n<div>\n<div class=\"gb-element-64bdb44f\">\n<section class=\"wh-contact\">\n  <div class=\"wh-contact__left\">\n    <h2>HOW CAN WE HELP YOU?<\/h2>\n  <\/div>\n\n  <div class=\"wh-contact__right\">\n    <div class=\"wh-contact__info\">\n              <div class=\"wh-contact__label\">Head of Sales &#8211; Field Sales &amp; Development<\/div>\n      \n      \n      <div class=\"wh-contact__name\">Dr.-Ing. Gerald Fees<\/div>\n\n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-telephone-fill\" viewBox=\"0 0 16 16\"> <path fill-rule=\"evenodd\" d=\"M1.885.511a1.745 1.745 0 0 1 2.61.163L6.29 2.98c.329.423.445.974.315 1.494l-.547 2.19a.68.68 0 0 0 .178.643l2.457 2.457a.68.68 0 0 0 .644.178l2.189-.547a1.75 1.75 0 0 1 1.494.315l2.306 1.794c.829.645.905 1.87.163 2.611l-1.034 1.034c-.74.74-1.846 1.065-2.877.702a18.6 18.6 0 0 1-7.01-4.42 18.6 18.6 0 0 1-4.42-7.009c-.362-1.03-.037-2.137.703-2.877z\"><\/path><\/svg><\/span>\n          <a href=\"tel:044219911-54\">\n            04421 9911-54          <\/a>\n        <\/div>\n      \n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-envelope-fill\" viewBox=\"0 0 16 16\"> <path d=\"M.05 3.555A2 2 0 0 1 2 2h12a2 2 0 0 1 1.95 1.555L8 8.414zM0 4.697v7.104l5.803-3.558zM6.761 8.83l-6.57 4.027A2 2 0 0 0 2 14h12a2 2 0 0 0 1.808-1.144l-6.57-4.027L8 9.586zm3.436-.586L16 11.801V4.697z\"><\/path><\/svg><\/span>\n          <a href=\"mailto:info@wessel-hydraulik.de\">\n            info@wessel-hydraulik.de          <\/a>\n        <\/div>\n      \n          <\/div>\n\n          <div class=\"wh-contact__img\">\n        <img decoding=\"async\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2025\/12\/Gerrald-Fees.jpg\" alt=\"Dr.-Ing. Gerald Fees\" loading=\"lazy\">\n      <\/div>\n      <\/div>\n<\/section>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>6\/2-way directional valve Application description 6\/2-way directional valve D62-2X 150, 250, 400 l\/min&nbsp;&nbsp; A 6\/2-way directional valve allows the volume flow downstream of a main section to be distributed to a choice of 2 consumers.The directional valves are available in two versions: 6-3 directional valve with a middle position, 6-2 directional valve without a middle &#8230; <a title=\"6\/2 Directional Control Valve D62-2X\" class=\"read-more\" href=\"https:\/\/wessel-hydraulik.de\/en\/6-2-directional-control-valve-d62-2x\/\" aria-label=\"Read more about 6\/2 Directional Control Valve D62-2X\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":72,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2687","page","type-page","status-publish"],"acf":[],"_links":{"self":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2687","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/comments?post=2687"}],"version-history":[{"count":2,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2687\/revisions"}],"predecessor-version":[{"id":2691,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2687\/revisions\/2691"}],"wp:attachment":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/media?parent=2687"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}