{"id":2693,"date":"2026-01-22T13:33:56","date_gmt":"2026-01-22T12:33:56","guid":{"rendered":"https:\/\/wesselweb.headandcode.dev\/pump-preload-valve-for-axial-piston-pumps\/"},"modified":"2026-07-09T23:06:52","modified_gmt":"2026-07-09T21:06:52","slug":"pump-preload-valve-for-axial-piston-pumps","status":"publish","type":"page","link":"https:\/\/wessel-hydraulik.de\/en\/pump-preload-valve-for-axial-piston-pumps\/","title":{"rendered":"Pump Preload Valve for Axial Piston Pumps"},"content":{"rendered":"\n<div class=\"gb-element-b3337877 wh-hero wh-hero--image\">\n<div class=\"gb-element-b07c2792 wh-hero__content \">\n<h1 class=\"gb-text wh-hero__title\"><strong>Pump Preload Valve for Axial Piston Pumps<\/strong><\/h1>\n\n\n\n<p class=\"gb-text gb-text-745317cd wh-hero__subtitle\">Application description<\/p>\n<\/div>\n<\/div>\n\n<div class=\"wh-tiles\">\n<div class=\"gb-element-c49075ab\">\n<h2 class=\"gb-text gb-text-1969cbe8\">Pump Preload Valve for Axial Piston Pumps&nbsp;&nbsp;<\/h2>\n\n\n\n<p class=\"gb-text gb-text-f167af0c\">Some variable displacement pumps, such as the Parker PV series axial piston pumps, require a minimum pressure of 20 bar for proper operation. This can be applied by a preload valve. The Wessel preload valve is available in connection sizes \u00be&#8221; to 1 1\/4&#8243;. It is mounted as an intermediate block directly onto the pump connection. In the valve, the flow is preloaded by a valve cone. The preload pressure is applied constantly and without loss by a pressure reducing valve. The valve is typically set to 20 bar. If the pump pressure exceeds the preload pressure, the valve opens completely and the volume flow is passed on with virtually no loss. Two connections P1 and MP are available upstream of the preload valve, from which a pilot pressure supply could be tapped, for example.        <\/p>\n<\/div>\n<\/div>\n\n<div class=\"gb-element-a8f64ca5\">\n<div class=\"gb-element-5473df5a\">\n<div class=\"gb-element-79ea1676\">\n<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"180\" class=\"gb-media-fb976e24\" alt=\"438.063.403.9_\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/438.063.403.9_20x12_kleiner-300x180.jpg\" title=\"438.063.403.9_20x12_kleiner\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/438.063.403.9_20x12_kleiner-300x180.jpg 300w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/438.063.403.9_20x12_kleiner-1024x615.jpg 1024w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/438.063.403.9_20x12_kleiner-768x461.jpg 768w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/438.063.403.9_20x12_kleiner.jpg 1181w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\n<\/div>\n\n\n\n<div>\n<h2 class=\"gb-text gb-text-172030b3\"><strong>Features<\/strong><\/h2>\n\n\n\n<p class=\"gb-text\">&#8211; suitable for axial piston pumps<br\/>&#8211; connection sizes 3\/4&#8243;; 1&#8243;; 1 1\/4&#8243;<br><br><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-494cffc3\">\n<h2 class=\"gb-text gb-text-25db1b89\"><strong>Circuit Diagram<\/strong><\/h2>\n\n\n\n<img loading=\"lazy\" decoding=\"async\" width=\"1181\" height=\"709\" class=\"gb-media-37a7a29f\" alt=\"Schaltschema-fc11d\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschema-fc11d.jpg\" title=\"Schaltschema-fc11d\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschema-fc11d.jpg 1181w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschema-fc11d-300x180.jpg 300w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschema-fc11d-1024x615.jpg 1024w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschema-fc11d-768x461.jpg 768w\" sizes=\"auto, (max-width: 1181px) 100vw, 1181px\" \/>\n<\/div>\n<\/div>\n\n<div>\n<div class=\"gb-element-64bdb44f\">\n<section class=\"wh-contact\">\n  <div class=\"wh-contact__left\">\n    <h2>HOW CAN WE HELP YOU?<\/h2>\n  <\/div>\n\n  <div class=\"wh-contact__right\">\n    <div class=\"wh-contact__info\">\n              <div class=\"wh-contact__label\">Head of Sales &#8211; Field Sales &amp; Development<\/div>\n      \n      \n      <div class=\"wh-contact__name\">Dr.-Ing. Gerald Fees<\/div>\n\n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-telephone-fill\" viewBox=\"0 0 16 16\"> <path fill-rule=\"evenodd\" d=\"M1.885.511a1.745 1.745 0 0 1 2.61.163L6.29 2.98c.329.423.445.974.315 1.494l-.547 2.19a.68.68 0 0 0 .178.643l2.457 2.457a.68.68 0 0 0 .644.178l2.189-.547a1.75 1.75 0 0 1 1.494.315l2.306 1.794c.829.645.905 1.87.163 2.611l-1.034 1.034c-.74.74-1.846 1.065-2.877.702a18.6 18.6 0 0 1-7.01-4.42 18.6 18.6 0 0 1-4.42-7.009c-.362-1.03-.037-2.137.703-2.877z\"><\/path><\/svg><\/span>\n          <a href=\"tel:044219911-54\">\n            04421 9911-54          <\/a>\n        <\/div>\n      \n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-envelope-fill\" viewBox=\"0 0 16 16\"> <path d=\"M.05 3.555A2 2 0 0 1 2 2h12a2 2 0 0 1 1.95 1.555L8 8.414zM0 4.697v7.104l5.803-3.558zM6.761 8.83l-6.57 4.027A2 2 0 0 0 2 14h12a2 2 0 0 0 1.808-1.144l-6.57-4.027L8 9.586zm3.436-.586L16 11.801V4.697z\"><\/path><\/svg><\/span>\n          <a href=\"mailto:info@wessel-hydraulik.de\">\n            info@wessel-hydraulik.de          <\/a>\n        <\/div>\n      \n          <\/div>\n\n          <div class=\"wh-contact__img\">\n        <img decoding=\"async\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2025\/12\/Gerrald-Fees.jpg\" alt=\"Dr.-Ing. Gerald Fees\" loading=\"lazy\">\n      <\/div>\n      <\/div>\n<\/section>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Pump Preload Valve for Axial Piston Pumps Application description Pump Preload Valve for Axial Piston Pumps&nbsp;&nbsp; Some variable displacement pumps, such as the Parker PV series axial piston pumps, require a minimum pressure of 20 bar for proper operation. This can be applied by a preload valve. The Wessel preload valve is available in connection &#8230; <a title=\"Pump Preload Valve for Axial Piston Pumps\" class=\"read-more\" href=\"https:\/\/wessel-hydraulik.de\/en\/pump-preload-valve-for-axial-piston-pumps\/\" aria-label=\"Read more about Pump Preload Valve for Axial Piston Pumps\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":74,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2693","page","type-page","status-publish"],"acf":[],"_links":{"self":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2693","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/comments?post=2693"}],"version-history":[{"count":2,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2693\/revisions"}],"predecessor-version":[{"id":2696,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2693\/revisions\/2696"}],"wp:attachment":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/media?parent=2693"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}