{"id":2813,"date":"2026-01-22T09:54:37","date_gmt":"2026-01-22T08:54:37","guid":{"rendered":"https:\/\/wesselweb.headandcode.dev\/62-directional-control-valve-position-monitoring\/"},"modified":"2026-07-10T00:24:38","modified_gmt":"2026-07-09T22:24:38","slug":"62-directional-control-valve-position-monitoring","status":"publish","type":"page","link":"https:\/\/wessel-hydraulik.de\/en\/62-directional-control-valve-position-monitoring\/","title":{"rendered":"62-directional-control-valve-position-monitoring"},"content":{"rendered":"\n<div class=\"gb-element-b3337877 wh-hero wh-hero--image\">\n<div class=\"gb-element-b07c2792 wh-hero__content \">\n<h1 class=\"gb-text wh-hero__title\"><strong>6\/2 Directional Control Valve with Position Monitoring<\/strong><\/h1>\n\n\n\n<p class=\"gb-text gb-text-745317cd wh-hero__subtitle\">Application description<\/p>\n<\/div>\n<\/div>\n\n<div class=\"wh-tiles\">\n<div class=\"gb-element-c49075ab\">\n<h2 class=\"gb-text gb-text-1969cbe8\">6\/2-way directional valve&nbsp;<\/h2>\n\n\n\n<p class=\"gb-text gb-text-f167af0c\">A 6\/2 directional control valve allows the volume flow downstream of a main section to be distributed to 2 consumers as required. The switching can be performed electrically, hydraulically, or via manual lever on the pilot control of the 6\/2 directional control valve. A position monitoring system allows the actual switching position of the directional control valve to be monitored and processed by a safety controller.<\/p>\n<\/div>\n<\/div>\n\n<div class=\"gb-element-a8f64ca5\">\n<div class=\"gb-element-5473df5a\">\n<div class=\"gb-element-79ea1676\">\n<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"180\" class=\"gb-media-fb976e24\" alt=\"\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/wegeventilS62_stellungsueberwachung_20x12_150dpi_1181x709-300x180.jpg\" title=\"directional-control-valve-S62-position-monitoring-20x12-150dpi-1181x709\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/wegeventilS62_stellungsueberwachung_20x12_150dpi_1181x709-300x180.jpg 300w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/wegeventilS62_stellungsueberwachung_20x12_150dpi_1181x709-1024x614.jpg 1024w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/wegeventilS62_stellungsueberwachung_20x12_150dpi_1181x709-768x461.jpg 768w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/05\/wegeventilS62_stellungsueberwachung_20x12_150dpi_1181x709.jpg 1182w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/>\n<\/div>\n\n\n\n<div>\n<h2 class=\"gb-text gb-text-172030b3\"><strong>Features<\/strong><\/h2>\n\n\n\n<p class=\"gb-text\">&#8211; Simple system expansion with an additional function<br\/>&#8211; High switching reliability<br\/>&#8211; Easy installation between the main control and two actuators<br\/>&#8211; Low pressure drop<br\/>&#8211; Flow rates up to 400 l\/min (higher on request)<br\/>&#8211; Pressure range 420 bar<br\/>&#8211; Additional sandwich plate with external pilot supply for use in closed circuits<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"gb-element-ecfb0e85\">\n<div class=\"gb-element-0e08f7c9\">\n<img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"541\" class=\"gb-media-3a3b8ff5\" alt=\"Circuit_diagrams_new\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu-zwischenplatte-768x541.jpg\" title=\"circuit-diagram-ai-new-sandwich-plate\" srcset=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu-zwischenplatte-768x541.jpg 768w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu-zwischenplatte-300x211.jpg 300w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu-zwischenplatte-1024x721.jpg 1024w, https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2026\/01\/Schaltschemenai_neu-zwischenplatte.jpg 1213w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/>\n<\/div>\n\n\n\n<div>\n<h2 class=\"gb-text gb-text-e0c54812\"><strong>Circuit Diagram<\/strong><\/h2>\n\n\n\n<p class=\"gb-text\">&#8211; 1,2 From the main control<br\/>&#8211; 3,4 Actuator 1 connection<br\/>&#8211; 5,6 Actuator 2 connection<br\/>&#8211; 7&nbsp;&nbsp;&nbsp;&nbsp;  Pump<br\/>&#8211; 8&nbsp;&nbsp;&nbsp;&nbsp;  Main control<br\/>&#8211; 9&nbsp;&nbsp;&nbsp;&nbsp;  6\/2-way directional control valve<br\/>&#8211; 10&nbsp;&nbsp;&nbsp;  Actuator 1<br\/>&#8211; 11&nbsp;&nbsp;&nbsp;&nbsp;Actuator 2<br\/>&#8211; 12&nbsp;&nbsp;&nbsp;  Sandwich plate<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n<div class=\"gb-element-a627f053\">\n<h2 class=\"gb-text gb-text-1c1940b5\"><strong>Applications<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Excavator<\/li>\n\n\n\n<li>Wheel loader<\/li>\n\n\n\n<li>Material handling machines<\/li>\n\n\n\n<li>Drilling technology<\/li>\n<\/ul>\n<\/div>\n\n<div>\n<div class=\"gb-element-64bdb44f\">\n<section class=\"wh-contact\">\n  <div class=\"wh-contact__left\">\n    <h2>HOW CAN WE HELP YOU?<\/h2>\n  <\/div>\n\n  <div class=\"wh-contact__right\">\n    <div class=\"wh-contact__info\">\n              <div class=\"wh-contact__label\">Head of Sales &#8211; Field Sales &amp; Development<\/div>\n      \n      \n      <div class=\"wh-contact__name\">Dr.-Ing. Gerald Fees<\/div>\n\n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-telephone-fill\" viewBox=\"0 0 16 16\"> <path fill-rule=\"evenodd\" d=\"M1.885.511a1.745 1.745 0 0 1 2.61.163L6.29 2.98c.329.423.445.974.315 1.494l-.547 2.19a.68.68 0 0 0 .178.643l2.457 2.457a.68.68 0 0 0 .644.178l2.189-.547a1.75 1.75 0 0 1 1.494.315l2.306 1.794c.829.645.905 1.87.163 2.611l-1.034 1.034c-.74.74-1.846 1.065-2.877.702a18.6 18.6 0 0 1-7.01-4.42 18.6 18.6 0 0 1-4.42-7.009c-.362-1.03-.037-2.137.703-2.877z\"><\/path><\/svg><\/span>\n          <a href=\"tel:044219911-54\">\n            04421 9911-54          <\/a>\n        <\/div>\n      \n              <div class=\"wh-contact__row\">\n          <span class=\"wh-contact__icon\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"16\" height=\"16\" fill=\"currentColor\" class=\"bi bi-envelope-fill\" viewBox=\"0 0 16 16\"> <path d=\"M.05 3.555A2 2 0 0 1 2 2h12a2 2 0 0 1 1.95 1.555L8 8.414zM0 4.697v7.104l5.803-3.558zM6.761 8.83l-6.57 4.027A2 2 0 0 0 2 14h12a2 2 0 0 0 1.808-1.144l-6.57-4.027L8 9.586zm3.436-.586L16 11.801V4.697z\"><\/path><\/svg><\/span>\n          <a href=\"mailto:info@wessel-hydraulik.de\">\n            info@wessel-hydraulik.de          <\/a>\n        <\/div>\n      \n          <\/div>\n\n          <div class=\"wh-contact__img\">\n        <img decoding=\"async\" src=\"https:\/\/wessel-hydraulik.de\/wp-content\/uploads\/2025\/12\/Gerrald-Fees.jpg\" alt=\"Dr.-Ing. Gerald Fees\" loading=\"lazy\">\n      <\/div>\n      <\/div>\n<\/section>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>6\/2 Directional Control Valve with Position Monitoring Application description 6\/2-way directional valve&nbsp; A 6\/2 directional control valve allows the volume flow downstream of a main section to be distributed to 2 consumers as required. The switching can be performed electrically, hydraulically, or via manual lever on the pilot control of the 6\/2 directional control valve. &#8230; <a title=\"62-directional-control-valve-position-monitoring\" class=\"read-more\" href=\"https:\/\/wessel-hydraulik.de\/en\/62-directional-control-valve-position-monitoring\/\" aria-label=\"Read more about 62-directional-control-valve-position-monitoring\">Read more<\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":77,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-2813","page","type-page","status-publish"],"acf":[],"_links":{"self":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2813","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/comments?post=2813"}],"version-history":[{"count":2,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2813\/revisions"}],"predecessor-version":[{"id":2816,"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/pages\/2813\/revisions\/2816"}],"wp:attachment":[{"href":"https:\/\/wessel-hydraulik.de\/en\/wp-json\/wp\/v2\/media?parent=2813"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}